INSTRUCTION SHEET
WARNING
1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico,com and from your ERICO customer
service representative.
2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.
4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as
appropriate to the application.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are registered trademarks of ERICO International Corporation
TECHNICAL SUPPORT: PDF084_E 1 of 1 2001, 2003, 2005, 2010,2012
www.erico.com ERICO International Corporation.
Figure 1
Figure 2 Figure 3 Figure 4
LENTON
FORM SAVER Assemblies
(North America)
Step 5: If the coupler and/or rebar is epoxy coated, refer to “Field Touch Up
Recommendations for Epoxy Coated
Couplers” Instruction Sheet PDF056. Additional copies of instructi
ons and application information are available at
www.erico.com.
Step 4: NOTE! Ensure that the correct LENTON taper threaded rebar is utilized. Ensure dowel thread protection is removed.
Ensure that the coupler and rebar dowel threads are clean and free of rust, concrete slurry, etc (Figure 3). Clean as required
using wire brush. Install rebar dowel hand tight, approx. 4-1/2 turns clockwise. Use a pipe wrench to tighten securely (Figure 4).
Refer to Table 1 for torque required to complete installation. The LENTON brand of inspection wrench can be used by inspectors
to periodically check tightness.
Step 2: Install coupler assembly parallel
with rebar to be spliced (Figure 1).
Position nailer plate flush to form. Attach
plate using nails, etc. Complete the tying
off of the rebar. Ensure that assembly is
properly supported to prevent movement
before or during the pour. WARNING:
The nailer flange is NOT intended to
support the weight of rebar, installer or
equipment.
INSTALLATION:
Step 1: Ensure the LENTON FORM
SAVER is sized properly with project
plans. Check and ensure proper
installation of coupler thread protection
prior to mounting to formwork.
LENTON FORM SAVER assemblies are 2-piece assemblies designed for
segmental pour construction methods. The tapered threaded coupler is
factory attached to the rebar either by friction welding or a LENTON taper
threaded connection. A separate rebar (dowel) is provided with matching
external tapered threads.
LENTON FORM SAVER assemblies are shipped from regional locations
The nailer plates are factory installed to ease the installation of LENTON
FORM SAVER’S to existing concrete forms. The female coupler assembly
is also furnished with short term thread protection.
Step 3: After forms are stripped, ensure
that thread protection on couplers are
removed prior to installation of male
dowel (Figure 2).
Table 1
in.-lb. Metric Canada Nm ft.-lb.
#3 10 --- 40 30
#4 12 10M 40 30
--- 14 --- 80 60
#5 16 15M 120 90
--- 18 --- 150 110
#6 20 20M 180 130
#7 22 --- 220 160
--- 24 --- 270 200
#8 25 25M 270 200
--- 26 26M 270 200
#9 28 30M 270 200
--- 30 --- 300 200*
#10 32 --- 300 200*
--- 34 --- 300 200*
#11 36 35M 300 200*
+Metric and imperial table values are not a direct conversion.
*Americas only
Ø
+